HR Single Cartridge Mechanical Seals – Replacement for EagleBurgmann HR
The Formax HJHR mechanical seal is offered for selected EagleBurgmann HR replacement applications in industrial pumps. Material options include carbon graphite, reaction-bonded silicon carbide, sintered silicon carbide and tungsten carbide, with elastomers and metal components selected for the service conditions.
The supplier’s dimension table covers sizes from 20 to 250 mm under the Size/d1 designation. Replacement selection requires confirmation of the installation arrangement and all relevant drawing dimensions.
- Product Introduction
HJHR is a mechanical seal replacement option for pump maintenance and refurbishment projects involving HR-type installations.
Selection considers the pump configuration, installation direction, seal chamber geometry, process liquid and operating conditions. For abrasive or solids-containing liquids, the review should also include particle size, solids concentration, settling behaviour and lubrication at the seal faces.
The supplied assembly must be matched to the existing installation. The HR family reference alone does not establish interchangeability with every HR variant.
- Product Specifications
| Item | Specification |
|---|---|
| Brand | Formax |
| Model | HJHR |
| Replacement reference | Selected EagleBurgmann HR installations |
| Supplier-listed size range | Size/d1: 20–250 mm |
| Corresponding dN range in the supplied table | 36–270 mm |
| Seal chamber temperature | −20 to +160°C / −4 to +320°F |
| Seal chamber pressure | Up to 16 bar / 1.6 MPa / approximately 232 psi |
| Sliding velocity | Up to 10 m/s / approximately 33 ft/s |
| Seal face options | Carbon graphite, RB-SiC, SSiC and tungsten carbide |
| Secondary seal options | NBR, FKM, EPDM and FFKM |
| Spring and metal options | SS304, SS316 and specified nickel alloys |
| Installation configuration | To be confirmed against the approved assembly drawing |
Operating figures are supplier-stated limits. Maximum temperature, pressure and sliding velocity are not necessarily available simultaneously. Final limits depend on the seal configuration, materials, size, process liquid and lubrication conditions.
- Material Options
| Component | Material Options | Selection Notes |
|---|---|---|
| Seal faces and mating rings | Carbon graphite | Specify the grade and impregnation for the application |
| Seal faces and mating rings | Reaction-bonded silicon carbide — RB-SiC | Review chemical compatibility and operating conditions |
| Seal faces and mating rings | Sintered silicon carbide — SSiC | Consider for suitable abrasive and chemically demanding services |
| Seal faces and mating rings | Tungsten carbide — TC | Confirm binder grade and chemical compatibility |
| Secondary seals | NBR | For compatible oil and selected water services |
| Secondary seals | FKM | For compatible oils, chemicals and temperature conditions |
| Secondary seals | EPDM | For compatible water and chemical services |
| Secondary seals | FFKM | Compound-specific selection for demanding chemical applications |
| Springs and metal components | SS304 / SS316 | Grade selected according to the service environment |
| Springs and metal components | Specified nickel alloy | Exact alloy designation requires confirmation |
Material availability does not establish suitability for every medium. Specify the complete face pairing, elastomer compound and metal grades when ordering.
- Applications
HJHR can be assessed for replacement projects involving the following equipment and services:
| Application | Selection Considerations |
|---|---|
| Wastewater pumps | Solids content, fibres, contaminants and operating cycles |
| Slurry and suspension pumps | Particle size, abrasiveness, concentration and settling |
| Pulp and paper pumps | Fibre content, process chemistry and lubrication |
| Chemical process pumps | Chemical compatibility, temperature and pressure |
| Mining and mineral-processing pumps | Abrasive wear, slurry properties and pump configuration |
| FGD suspension pumps | Process chemistry, solids and corrosion conditions |
| Dredging equipment | Severe abrasion and installation-specific requirements |
| General industrial pumps | Existing seal geometry and operating conditions |
Application suitability requires a review of the actual service conditions. No universal solids concentration or dry-running capability is implied.
- Dimensions — HJHR
All dimensions are in millimetres.
The following tables reproduce the HJ supplier’s data. Read them together with the corresponding installation drawing. Size, d1, d1h and dN are separate drawing references and must not be used interchangeably.


- Table A — Principal Diameter Dimensions
| Size | d1 | d1h | dN | d2 | d3 | d4 | d5 | d6 | d7 |
|---|---|---|---|---|---|---|---|---|---|
| 20 | 20 | 28 | 36 | 47.1 | 65 | 70 | 46 | 56.0 | 63.0 |
| 25 | 25 | 33 | 41 | 52.1 | 70 | 75 | 51 | 62.0 | 70.0 |
| 28 | 28 | 38 | 46 | 57.1 | 75 | 80 | 56 | 67.0 | 75.0 |
| 33 | 33 | 43 | 51 | 62.1 | 80 | 85 | 61 | 72.0 | 80.0 |
| 38 | 38 | 48 | 56 | 67.1 | 85 | 90 | 66 | 77.0 | 85.0 |
| 43 | 43 | 53 | 61 | 72.1 | 90 | 95 | 69 | 81.0 | 90.0 |
| 48 | 48 | 58 | 66 | 77.1 | 95 | 100 | 76 | 88.0 | 97.0 |
| 53 | 53 | 63 | 71 | 82.1 | 101 | 105 | 81 | 95.0 | 105.0 |
| 55 | 55 | 65 | 75 | 87.1 | 106 | 110 | 86 | 100.0 | 110.0 |
| 60 | 60 | 70 | 80 | 92.1 | 111 | 115 | 91 | 105.0 | 115.0 |
| 65 | 65 | 75 | 85 | 97.1 | 116 | 120 | 96 | 110.0 | 120.0 |
| 70 | 70 | 80 | 90 | 102.1 | 121 | 125 | 101 | 115.0 | 125.0 |
| 75 | 75 | 85 | 95 | 107.1 | 126 | 130 | 107 | 122.2 | 134.3 |
| 80 | 80 | 90 | 100 | 112.1 | 131 | 135 | 107 | 122.2 | 134.3 |
| 90 | 90 | 100 | 110 | 126.1 | 147 | 155 | 117 | 136.2 | 148.3 |
| 100 | 100 | 110 | 120 | 136.1 | 157 | 165 | 132 | 146.2 | 158.3 |
| 110 | 110 | 120 | 130 | 145.1 | 167 | 175 | 142 | 156.2 | 168.3 |
| 120 | 120 | 130 | 140 | 154.1 | 177 | 185 | 152 | 168.2 | 180.3 |
| 130 | 130 | 140 | 150 | 163.9 | 188 | 195 | 162 | 178.2 | 190.3 |
| 140 | 140 | 150 | 160 | 174.9 | 189 | 205 | 172 | 188.2 | 200.3 |
| 160 | 160 | 170 | 180 | 193.9 | 220 | 230 | 187 | 212.5 | 224.3 |
| 180 | 180 | 190 | 200 | 213.9 | 240 | 255 | — | — | — |
| 190 | 190 | 200 | 210 | 231.9 | 255 | 270 | — | — | — |
| 200 | 200 | 210 | 220 | 241.9 | 265 | 280 | — | — | — |
| 210 | 210 | 220 | 230 | 251.9 | 275 | 290 | — | — | — |
| 220 | 220 | 230 | 240 | 261.8 | 285 | 300 | — | — | — |
| 230 | 230 | 240 | 250 | 271.9 | 295 | 310 | — | — | — |
| 250 | 250 | 260 | 270 | 291.9 | 315 | 330 | — | — | — |
- Table B — Additional Diameter and Detail Dimensions
| Size | d8 | d9 | d10 | d11 +0.2 min.* | k2 | t | t1 |
|---|---|---|---|---|---|---|---|
| 20 | 4 | 40 | 38 | 75 | 51.0 | 4.5 | 3 |
| 25 | 4 | 45 | 43 | 80 | 56.5 | 4.5 | 3 |
| 28 | 4 | 50 | 48 | 85 | 61.5 | 4.5 | 3 |
| 33 | 4 | 55 | 53 | 90 | 66.5 | 4.5 | 3 |
| 38 | 4 | 60 | 58 | 95 | 71.5 | 4.5 | 3 |
| 43 | 4 | 65 | 63 | 100 | 75.0 | 4.5 | 3 |
| 48 | 4 | 70 | 68 | 105 | 82.0 | 4.5 | 3 |
| 53 | 4 | 75 | 73 | 110 | 88.0 | 4.5 | 3 |
| 55 | 4 | 79 | 78 | 115 | 93.0 | 4.5 | 3 |
| 60 | 4 | 84 | 83 | 120 | 98.0 | 4.5 | 3 |
| 65 | 4 | 89 | 88 | 125 | 103.0 | 4.5 | 3 |
| 70 | 4 | 94 | 93 | 130 | 108.0 | 4.5 | 3 |
| 75 | 5 | 99 | 98 | 135 | 114.5 | 7.0 | 3 |
| 80 | 5 | 104 | 103 | 140 | 114.5 | 7.0 | 3 |
| 90 | 5 | 116 | 117 | 163 | 126.5 | 7.0 | 4 |
| 100 | 5 | 126 | 127 | 173 | 139.0 | 7.0 | 4 |
| 110 | 5 | 136 | 136 | 183 | 149.0 | 7.0 | 4 |
| 120 | 5 | 146 | 145 | 193 | 160.0 | 7.0 | 4 |
| 130 | 5 | 156 | 155 | 203 | 170.0 | 7.0 | 4 |
| 140 | 5 | 166 | 166 | 213 | 180.0 | 7.0 | 4 |
| 160 | 5 | 186 | 185 | 238 | 199.5 | 7.0 | 4 |
| 180 | — | 206 | 205 | 265 | — | — | 4 |
| 190 | — | 218 | 220 | 280 | — | — | 5 |
| 200 | — | 228 | 230 | 290 | — | — | 5 |
| 210 | — | 238 | 240 | 300 | — | — | 5 |
| 220 | — | 248 | 250 | 310 | — | — | 5 |
| 230 | — | 258 | 260 | 320 | — | — | 5 |
| 250 | — | 278 | 280 | 340 | — | — | 5 |
The d11 column heading follows the supplier’s notation. Confirm the tolerance requirement on the approved installation drawing.
- Table C — Axial Dimensions
| Size | L | L1 | L2 | L3 | L4 | L5 | L6 | L7 | L9 |
|---|---|---|---|---|---|---|---|---|---|
| 20 | 75 | 53 | 20 | 19.5 | 17 | 10.5 | 6 | 9 | 8.0 |
| 25 | 75 | 53 | 20 | 19.5 | 17 | 10.5 | 6 | 9 | 9.5 |
| 28 | 75 | 53 | 20 | 19.5 | 17 | 10.5 | 6 | 9 | 9.5 |
| 33 | 75 | 53 | 20 | 19.5 | 17 | 10.5 | 6 | 9 | 10.5 |
| 38 | 75 | 53 | 20 | 19.5 | 17 | 10.5 | 6 | 9 | 10.5 |
| 43 | 75 | 53 | 20 | 19.5 | 17 | 10.5 | 7 | 9 | 11.0 |
| 48 | 75 | 53 | 20 | 19.5 | 17 | 10.5 | 7 | 9 | 11.5 |
| 53 | 75 | 53 | 20 | 19.5 | 17 | 10.5 | 7 | 9 | 11.5 |
| 55 | 75 | 53 | 20 | 19.5 | 17 | 10.5 | 7 | 9 | 11.5 |
| 60 | 75 | 53 | 20 | 19.5 | 17 | 10.5 | 7 | 9 | 13.0 |
| 65 | 75 | 53 | 20 | 19.5 | 17 | 10.5 | 7 | 9 | 13.0 |
| 70 | 75 | 53 | 20 | 19.5 | 17 | 10.5 | 7 | 9 | 13.0 |
| 75 | 75 | 53 | 20 | 19.5 | 17 | 10.5 | 10 | 12 | 20.0 |
| 80 | 75 | 53 | 20 | 19.5 | 17 | 10.5 | 10 | 12 | 20.0 |
| 90 | 98 | 73 | 30 | 22.0 | 19 | 16.0 | 10 | 12 | 20.0 |
| 100 | 98 | 73 | 30 | 22.0 | 19 | 16.0 | 10 | 12 | 20.0 |
| 110 | 98 | 73 | 30 | 22.0 | 19 | 16.0 | 10 | 12 | 20.0 |
| 120 | 98 | 73 | 30 | 22.0 | 19 | 16.0 | 10 | 12 | 20.0 |
| 130 | 98 | 73 | 30 | 22.0 | 19 | 16.0 | 12 | 12 | 24.0 |
| 140 | 98 | 73 | 30 | 22.0 | 19 | 16.0 | 12 | 12 | 24.0 |
| 160 | 98 | 73 | 30 | 22.0 | 19 | 16.0 | 12 | 12 | 28.0 |
| 180 | 98 | 73 | 30 | 22.0 | 19 | 16.0 | — | — | — |
| 190 | 115 | 83 | 40 | 28.35 | 24.7 | 19.0 | — | — | — |
| 200 | 115 | 83 | 40 | 28.35 | 24.7 | 19.0 | — | — | — |
| 210 | 115 | 83 | 40 | 28.4 | 24.7 | 19.0 | — | — | — |
| 220 | 115 | 83 | 40 | 28.35 | 24.7 | 19.0 | — | — | — |
| 230 | 115 | 83 | 40 | 28.35 | 24.7 | 19.0 | — | — | — |
| 250 | 115 | 83 | 40 | 28.4 | 24.7 | 19.0 | — | — | — |
“—” indicates that no value is provided in the supplier’s table. It does not indicate zero.
Dimensions are for preliminary selection. Confirm all dimensions, fits, tolerances and installation details against an approved manufacturing drawing before ordering.
- Replacement Selection
For an EagleBurgmann HR replacement enquiry, provide the full existing seal designation and installation drawing.
The review should establish:
- Whether installation is from the impeller side or bearing side.
- The meaning and values of d1, d1h and dN on the existing drawing.
- The required component or cartridge configuration.
- Available radial and axial installation space.
- Seal face materials and secondary seal compounds.
- Process pressure, temperature and shaft speed.
- Solids concentration, particle size and abrasiveness.
- Flush, quench and vacuum operating requirements.
HR10, HR11, HR2, HR3, HRZ1 and HRKS-D must be assessed as distinct configurations.
- Installation and Operating Considerations
Correct installation depends on the supplied assembly and pump design. Confirm the installation direction, setting dimensions, axial movement and clearances before fitting the seal.
For vacuum operation, establish the atmosphere-side quench requirement for the selected configuration. Operation without external flushing must be approved for the actual liquid, solids loading and seal construction.
Dry-running capability is not established by the HJHR designation.
- Standards and Documentation
The HJ supplier references ISO 3069, DIN 24960 and GB 6556 in its product literature. These references do not establish interchangeability with every pump or HR variant.
Specify required drawings, material certificates, inspection reports and application-specific documentation with the enquiry.
- Frequently Asked Questions
Can HJHR replace an EagleBurgmann HR seal?
HJHR can be assessed for selected HR replacement applications. The existing seal configuration, installation dimensions, materials and service conditions must be matched before ordering.
Is HJHR always a cartridge seal?
The HJ supplier describes the product as a cartridge mechanical seal, but the supplied dimension table alone does not identify a specific HR cartridge variant. Confirm the actual assembly drawing and scope of supply.
Why are both 20–250 mm and 36–270 mm shown?
These ranges refer to different drawing symbols. In the supplied table, Size/d1 ranges from 20 to 250 mm, while dN ranges from 36 to 270 mm. Quote the symbol together with its value.
Is the seal suitable for slurry service?
Suitability depends on the particle size, concentration, abrasiveness, settling behaviour and lubrication conditions. Provide the slurry details for material and configuration selection.
Can the seal operate without flushing?
This requires application-specific approval. A no-flush claim must be supported by the supplied seal construction and actual process conditions.
- Request a Quote
For HJHR replacement selection, send:
| Required Information | Details |
|---|---|
| Existing seal | Brand, complete model and drawing number |
| Pump | Manufacturer, model and installation arrangement |
| Dimensions | Existing drawing, including d1, d1h and dN |
| Process liquid | Composition and concentration |
| Solids | Weight percentage, particle size and abrasiveness |
| Operating conditions | Pressure, temperature, rpm and vacuum conditions |
| Auxiliary services | Available flush or quench |
| Materials | Existing or requested material combination |
| Quantity | Required quantity and delivery destination |
Email: formaxfluid@hotmail.com
Formax is an independent aftermarket supplier and is not affiliated with EagleBurgmann. Third-party brand names and model references are used for identification and replacement assessment only.
Related products
-
Cartridge Mechanical Seals
HJ5620 Dual Cartridge Mechanical Seal — Replacement for John Crane Type 5620
Read more